MagFlux 7200

MagFlux 7200 sensor is produced with a Hard Rubber Liner.

The Hard Rubber liner of the MagFlux 7200 series, is used for general water purpose usage.

The MagFlux 7200 sensor series is delivered with EN, AS, ANSI, AWWA and KS  flanges
and standard ISO built-in length.

  • Tick
    Supports IP 68 installations
  • Tick
    Large sensor range,
    DN 20-1400 / 3/4" to 48"
  • Tick
    Small built-in lengths
  • Tick
    Velocity range from
    0.2 - 10 m/s / 0.6 - 30 ft./s
  • Tick
    Full bore sensors
  • Tick
    MID Certificate from
    DN25 to DN400, for metering of cold water.

MagFlux 7200 sensors are used to measure all kinds of waste water, from very slurry liquids to outlet water.
In many areas the MagFlux sensors is used to keep track of the Amounts of waste water pumped from an urban region, to a greater plant, often seen here is the large DN sizes.
MagFlux 7200 sensors from DN 50 to DN 400 can be delivered with MID certificate, this means the flow meter can be used to invoicing deliveries to and from clients – or in between plant as the counter cannot be reset.

The hard rubber lining of MagFlux 7200 is a typically all-round liner, used in harsh environments, like waste water.

In case of the potential risk of flooding of the flow sensor, the MagFlux flow sensors can be potted for IP68 protection.

MagFlux is used for measuring the flow of the raw water from ground water wells and pumps, to the treatment plant, logging and transferring the data of the amount of water delivered.

For drinking water networks, the MagFlux 7200 is used; this model also holds the WRAS certificate, issued for UK.

MagFlux series 7200 from DN 50 to DN 400 are MID certified; this means the flow meter can be used for billing purposes.

The MagFlux holds a feature for forward and reverse flow and a totalizer, deducting the reverse flow from forward flow. This means that e.g. when two waterworks are interconnected; MagFlux can totalize flow volume for both directions.

The Sensor can work in submerged conditions, having the converter mounted nearby. In this application, the sensor is IP68 secured.

For data collection, in order to trace the non-revenue water loss (NRW) the high accuracy of 0,25% at a velocity down to 0,2 m/s. including the build in data logger, provides these data easily.

MagFlux Provides exact measurements of water going into tanks or outlet water from aqua culture applications.

The sensor is constructed with 3 electrodes, and a 3-point calibration, which provides an excellent precision of only +/- 0,25% and measuring as low as 0,2 m/s.

The output from the MagFlux converter can, instead of the conventional 4/40mA loops, be provided as a ModBus RS485 signal.

In application where the sensor is installed closely, the MagFlux Display can handle up to 4 converters and sensors in a local network.

The MagFlux MID certification allows the totalizers to be used for documentation or invoicing or billing purpose.

For very heated water, highly corrosive or water containing other aggressive elements the 7100 lining PTFE is recommended. This lining is especially created for process fluids.
The Electrodes is created in Steel, Hastelloy, titanium or platinum, will match almost any usage.
MagFLux are NIST certified this means the flow meter can be used to invoicing deliveries to and from clients – or in between plant as the counter cannot be reset.
The output from the converter is RS485, and the converter can be wall mounted up to 1000m from the sensor, this is very common in larger waste water pumping facilities.
One MagFlux Display can handle 4 converters and sensors.

 

All MJK PRODUCTS ARE DELIVERED WITH A ONE YEAR FACTORY WARRANTY.
THE WARRANTY CAN BE EXTENDED BY UP TO FIVE YEARS.

The separate up to five years additional warranty contract must be ordered upon ordering of your MJK product.

MagFlux 7200 specifications

Mounting, Flanges
EN-1092-1 / ANSI B 16.5 / AWWA C207-01 / AS 4087 / AS 2129 / KS B 1503
Material, Lining
Hard Rubber
Built-in length
Standard length according to ISO 13359
Accuracy
Better than ± 0,25 %
Materials, Housing
Carbon steel, optional stainless steel AISI 304/316
Material, Flanges
Carbon steel, optional stainless steel
Material, Electrodes
Steel 1,4571 / AISI 316 TI, optional Hastelloy, platinium, and titanium